3X / 3X-G2 / 10X-720 / 10X Camera ID Configuration
- Look for the DIP switches on the bottom of the camera in the "SW1" group of DIP switches.
- Carefully adjust the DIP switches according to "PIC 1" to set the necessary ID for your camera
- Example(s) - PIC 1 showcases the settings for Camera ID 1, and PIC 2 showcases the settings for Camera ID 2
- Do this for each camera in the chain you wish to assign in the same fashion; Camera ID 3 would be with SW1 DIP Switch 3 UP and all others DOWN.
- Power on all you cameras.
12X Camera ID Configuration
- You will need to see the video output of the 12X via USB or DVI to set the appropriate address for each camera.
- Go to the OSD by pressing the "Menu" button on your remote and select "System Option".
- Make sure the "Protocol" is set to "VISCA", and your "B.Rate" is set to "9600".
- In the same menu, for the camera you have chosen to be Camera 1, set "ADDR" to be "001".
- Repeat step 4, with the minor variations noted, for any other camera(s) in the chain; Camera 2 would have an "ADDR" of "002", Camera 3 would be "ADDR" "003", etc...
- Power on all you cameras.
3XW / 3XW-G2 / 20X / 20X-G2 / 30X / 30X-G2 Camera ID Configuration
- These cameras can be set to control up to three (3) cameras via the DIP Switch settings (chart provided below).
- Decide which camera(s) you want to be Cam1, Cam2 and Cam3 respectively.
- Set the DIP Switches on the bottom of the camera as follows to set as Cam 1 (Cam ID1). Turn ON DIP Switch 5 making sure DIP Switch 4 is OFF.
- Set the DIP Switches on the bottom of the camera as follows to set as Cam 2 (Cam ID2). Turn ON DIP Switch 4making sure your DIP Switch 5 is OFF.
- Set the DIP Switches on the bottom of the camera as follows to set as Cam 3 (Cam ID3). Turn ON DIP Switch 4 and turning ON DIP Switch 5.
- Power on all you cameras.
DIP Switch 4 |
DIP Switch 5 |
|
Cam ID1 | OFF | ON |
Cam ID2 | ON | OFF |
Cam ID3 | ON | ON |